400KVA 30KVA Cummins Diesel Generator Delivered To Libya for Hospital Back Up Power
400KVA 30KVA Cummins diesel generator delivered hospitals in Syria as part of a UNDP aid project.
we have completed supply and commissioning of 10 sets of Cummins diesel generator set to Libya. The units are used as backup power for hospitals. It have been completely installed, tested, and are running with full load, the hospital now enjoyed reliable and stable power supply.
Breu introducció del projecte:
Potència nominal: 4 × 450 kVA i 6 × 30KVA
Tipus: Generador dièsel silenciós amb doset insonoritzat i a prova de pluja
Aplicació: Potència contínua / en espera per als hospitals
Aquest èxit d'instal·lació prova de nou el fet que podem proporcionar solucions d'energia fiables a clients globals en un Diversitat d'indústries.

Generator sets utilized in hospitals serve as the final line of defense in safeguarding human life. Far from being ordinary equipment, they constitute a highly automated emergency power system. Their core mission is to automatically activate within seconds of a utility power outage, thereby ensuring the uninterrupted operation of critical departments such as operating rooms and ICUs (Intensive Care Units).
The specialized nature of hospital generators is primarily reflected in the following aspects:
- Extremely Rapid Start-up Speed
This is the most critical performance metric. When utility power fails, the generator must automatically complete its start-up and power transfer sequence within a timeframe ranging from a few seconds to just over ten seconds, as a power interruption poses an extremely high risk to life-support equipment such as ventilators and patient monitors. Furthermore, for areas with exceptionally stringent requirements for power supply continuity—such as operating rooms—the generator is typically paired with a UPS (Uninterruptible Power Supply). The UPS is responsible for providing zero-delay power immediately following an outage, bridging the gap until the generator successfully starts up.
- Exceptional Reliability
In its role as a “backup” system, the generator may remain dormant for extended periods—potentially for years—yet it must be capable of responding instantly the moment it is called upon. Consequently, hospitals conduct regular operational drills—such as simulating a simultaneous failure of dual utility power feeds—and entrust the equipment to professional teams for meticulous maintenance.
- Strict Regulatory Compliance
The design and installation of hospital power generation systems must strictly adhere to national standards—such as the *Code for Electrical Design of Medical Buildings* (JGJ312-2013)—with particular emphasis on meeting the specific power supply requirements for “Level I Loads” (critical life-support areas like operating rooms and ICUs) and “Level II Loads” (essential support systems such as elevators and domestic water pumps).
- Specialized Installation and Environmental Requirements
Generators are frequently situated in hospital basements; therefore, issues regarding ventilation, exhaust emission, noise reduction, and seismic resistance must be addressed with meticulous care. For instance, the generator room requires specialized soundproofing construction, while exhaust ducts must undergo thermal insulation and noise-dampening treatments to minimize any adverse impact on the hospital environment.
- Intelligent Monitoring and Management
Modern hospital generator systems are typically equipped with “Three-Remote” (3R) systems—encompassing remote telemetry, remote signaling, and remote control capabilities. This technology enables facility managers to monitor critical parameters—such as fuel levels, coolant temperature, and voltage—in real-time from a central control room, thereby facilitating comprehensive remote management and control.
|
Generator Ratings |
|
Voltatge |
HZ |
Phase |
P.F |
Prime Amps |
Standby Power (KVA) |
Prime Potència (KVA) |
|
380/220V |
50 |
3 |
0.8 |
607 |
440 |
400 |
|
400/230V |
50 |
3 |
0.8 |
577 |
440 |
400 |
|
415/240V |
50 |
3 |
0.8 |
556 |
440 |
400 |
Prime power (PRP): Prime power is available for an unlimited number of annual hours in available load application, in according with GB/T2820-97(EQVLso8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby power Rating (ESP): The standby power rating is application for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
|
Sales Promises |
We provide a full line of brand new and high quality products. Each and every unit is strictly on load test before delivery. Warranty is according to our standard conditions: 12 months or 1500 running hour’s, subject to the earlier one. Service and parts are available from our factory or distribution in your location.
|
DADES DEL MOTOR |
|
Manufacturer /Model |
Cummins /6ZTAA13-G2 |
|
Air intake System |
Turbocharged & Charge Air Cooled |
|
Fuel System |
Direct injection |
|
Cylinder Arrangement |
6 in LINE |
|
Desplaçament |
13L |
|
Bore and Stroke |
130*163(MM) |
|
Compression Ratio |
17:1 |
|
Rated RPM |
1500rpm |
|
Prime power at Rated RPM |
390KW |
|
Max standby Power at Rated RPM |
415KW |
|
Governor Type |
electric |
|
Fuel System |
BYC PD/GAC |
|
Capacitat petroliera |
45.42L |
|
Coolant capacity |
73L |
|
Rated fuel consumption |
192g/kw.h at 100% load (71.7L/hr) |
|
ALTERNATOR SPECIFICATION |
|
General data |
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
|
Alternator Data |
|
Manufacture /Type |
Stamford / HCI444F1 |
|
Number of Phase |
three |
|
Connecting Type |
3 Phase and 4 wire Rotating Field |
|
Number of Bearing |
one |
|
Power Factor |
0.8 |
|
Protection Grade |
IP23 |
|
Altitude |
≤1000m |
|
Exciter Type |
Brush less, self-exciting |
|
Insulation Class, Temperature Rise |
H/H |
|
Capacity |
400KVA |
|
GENERATING SET DATA |
|
Voltage Regulation |
³±5% |
|
Voltage Regulation, Stead State |
£±1% |
|
Sudden Voltage Warp (100% Sudden Reduce) |
£+25% |
|
Sudden Voltage Warp (sudden Increase) |
£-20% |
|
Voltage Stable Time (100% sudden Reduce) |
£6s |
|
Voltage Stable Time (Sudden Increase) |
£6s |
|
Frequency Reduce |
£5% adjustable |
|
Frequency Regulation, Stead State |
£1.5% |
|
Frequency waving |
£0.8 % |
|
Sudden Frequency Warp (100% Sudden Reduce) |
£+12% |
|
Sudden Frequency Warp (Sudden Increase) |
£-10% |
|
Frequency Recovery Time (100% sudden Reduce) |
£5s |
|
Frequency Recovery Time (Sudden Increase) |
£5s |
Si necessita una solució de generador dièsel personalitzada, no dubti en contactar amb nosaltres UleengenSempre estem disposats a donar suport al teu projecte.
The gensets powered by Cummins QSZ13-G2 engine, ECU control. original Stamford alternator. automatic start with separated fuel tank.