    通过管理员

    750kVA Cummins generator set is a robust and reliable power solution for poultry farm

    750kVA Cummins generator set is a robust and reliable power solution for poultry farmwhere consistent power is critical for ventilation, heating, cooling, feeding, and overall bird welfare. UleenGen 750KVA Cummins diesel generator sets are delivered to a major integrated poultry farm in Philippines.

    Equipping a large-scale poultry farm with a 750 kVA Cummins diesel generator set is a highly prudent and essential decision. Under modern, high-density farming models, the availability of electricity is directly linked to both the survival of the flock and operational productivity. During the summer months, a power outage lasting just 30 minutes can cause the temperature inside the poultry house to skyrocket by 5–8°C—a rise sufficient to inflict massive economic losses. Consequently, a reliable and sufficiently powerful emergency power generation system serves as the “lifeline” of a poultry farm.

     

    以下是您需要考虑的内容的全面细分,从规模到特定的家禽养殖场要求。

    家禽养殖场的典型负荷:

    通风扇:最大的单一消费者。现代隧道通风房屋使用许多大型风扇(每个1-2马力)。
    加热系统:肉鸡、辐射加热器或空间加热器(尤其适用于肉鸡/雏鸡)。
    冷却系统:蒸发冷却垫及其泵。
    照明:受控照明程序至关重要。
    进料系统:自动进料线、螺旋钻和料仓搅拌器。
    供水系统:水泵和水管加压。
    鸡蛋收集系统:(用于蛋鸡养殖场)输送机、电梯、包装设备。
    Incubators & Hatchery Equipment: (If you have a hatchery) This is a massive, sensitive load.
    附属建筑:饲料厂、加工厂(如果在现场)、办公室。

     

    750KVA Cummins Diesel Generator Specifiation UC750GF

    Standby Power(60HZ)

    600KW/750KVA

    Prime Power(60HZ)

    545KW/682KVA

     

    Generator Ratings

    电压

    HZ

    Phase

    P.F

    Prime

    Amps

    Standby Power  

    (KVA)

    Prime Power 

    (KVA)

    220/127V

    60

    3

    0.8

    1787A

    750

    682

     

      Prime power (PRP): Prime power is available for an unlimited number of annual hours in available load application, in according with GB/T2820-97(EQVLso8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.

     

      Standby power Rating (ESP): The standby power rating is application for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.

     

    发动机数据

    Manufacturer /Model

    Cummins / KTAA19-G6A

    Air intake System

    Turbocharged, air to air inter cooler

    Fuel System

    direct injection

    Cylinder Arrangement

    6 inline

    位移

    18.9L

    Bore and Stroke

    159*159(MM)

    Compression Ratio

    13:1

    Rated RPM

    1800rpm

    Prime power at rated RPM

    603KW

    Max standby Power at Rated RPM

    664KW

    Governor Type

    electric

    油量

    50L

    Fuel System

    100%(Prime Power) Load

    197g/Kwh

    75%(Prime Power) Load

    202g/Kwh

    50%(Prime Power) Load

    214g/Kwh

    100%(Prime Power) Load

    118L/h

    Oil System

    Engine Oil Tank Capacity

    50L

    Min Oil Pressure at Rated RPM

    345kPa

    冷却系统

    Engine coolant capacity

    30L

    Thermostat

    82-93℃

    Max top tank Temperature

    104℃

    ALTERNATOR SPECIFICATION

    General data

    Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.

    Alternator Data

    Manufacture /Type

    Stamford technology alternator 5E

    Number of Phase

    three

    Connecting Type

    3 Phase and 4 wire

    Number of Bearing

    one

    Power Factor

    0.8

    Protection Grade

    IP23

    Altitude

    ≤1000m

    Exciter Type

    Brush less, self-exciting

    Insulation Class, Temperature Rise

    H/H

    Alternator Capacity

    750KVA

     

    Standard Supply scope of Cummins diesel generator set

    • General Features
    • Engine(Cummins KTAA19-G6A)
    • Radiator 50C max, fans are driven by belt
    • 24V starter and charge alternator
    • Alternator (5E )
    • Absorbers installed
    • 8hrs base fuel tank
    • Dual air filter ,fuel filter, oil filter, fuel water separator
    • Circuit breaker
    • Control panel with HGM6120 controller
    • Batteries and connecting wire.
    • Ripple flex exhaust pipe, bellows, flange, muffler.
    • User manual, test report, etc)