news
Home News Company News Uleengen Medium Voltage 13.8KV 1500KVA Diesel Generator Set Passed FAT | air base KTA50-G12A

Table of Contents

    Uleengen Medium Voltage 13.8KV 1500KVA Diesel Generator Set Passed FAT | air base KTA50-G12A

    2023-09-23 13:44:37
    By Admin

    Military generators sets are built to standards far exceeding typical commercial generator sets.

    1. Military use generator sets Extreme Reliability & Uptime: Mission-critical operations depend on uninterrupted power. Redundancy and simple maintenance are vital.

    2. Ruggedness & Durability: Must withstand severe shock, vibration, corrosion, sand, dust, rain, high altitude or temperature extremes (-40°C to +52°C is common).

    3. Mobility & Deployability: Often skid-mounted, trailer-mounted, or integrated into shelters (ISO containers) for rapid air, sea, and land transport.

    4. Powerful power output and load adaptability: Military generator sets typically have high power output capabilities, can support the operation of multiple devices simultaneously, and can adapt to high instantaneous loads.

    5. Low Observability: Reduced thermal, acoustic, and electromagnetic signatures to avoid detection.

    6. Tactical Quietness: Special acoustic enclosures and exhaust designs to lower the audible footprint for covert operations.

    7. Electromagnetic Interference (EMI) Control: Must not interfere with sensitive communications and radar equipment.

    8. Standardization & Compatibility: Adherence to military standards (MIL-STD) for connectors, voltages, and phases to ensure interoperability across all branches.

    1500 KVA CUMMINS DIESEL GENERATOR SPECIFICATION

    Model

    UC1500GFC

    Standby Power(60HZ)

    1320KW / 1650KVA

    Prime Power(60HZ)

    1200KW / 1500KVA

     

    Generator Ratings

     

    Voltage

    HZ

    Phase

    P.F

    Prime

    Amps

    Standby power  

     (KVA)

    Prime power 

    (KVA)

    13.8KV

    60

    3

    0.8

    62.8A

    1650

    1500

     

      Prime power (PRP): Prime power is available for an unlimited number of annual hours in available load application, in according with GB/T2820-97(EQVLso8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.

     

      Standby power Rating (ESP): The standby power rating is application for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.

     

    Sales Promises

     

    We provide a full line of brand new and high quality products. Each and every unit is strictly on load test before delivery. Warranty is according to our standard conditions: 12 months or 1500 running hour’s, subject to the earlier one. Service and parts are available from our factory or distribution in your location.

     

    ENGINE DATA

     

    Manufacturer /Model

    Cummins / KTA50-G12A

    Air intake System

    Turbocharged and air-air inter cooler

    Cooling system

    water cooled

    Cylinder Arrangement    

    16 cylinder V type 

    Displacement

    50.3L

    Bore and Stroke

    159*159(MM)

    Compression Ratio

    13.9:1

    Rated RPM

    1800rpm

    Prime power at rated RPM

    1347KW

    Max standby power at rated RPM

    1582KW

    Oil capacity

    148-178L

    Governor

    electric

    Fuel consumption@100% load

    280L/hr

    Max intake resistance (KPa)

    6.23

    Air intake (m3/h)

    5371

    Max exhaust back pressure (KPa)

    6.8

    Exhaust gas flow (m3/h)

    13374

    Exhaust temp (℃)

    503

    Cooling way

    Water Radiator & Fan

    Fan exhaust flow (m3/min)

    1700

    Coolant capacity (L)

    430

    Highest water temperature(℃)

    104

     

    ALTERNATOR SPECIFICATION

    General data

    Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.

    Alternator Data

     

    Brand /Model

    EvoTec TH528B

    Number of Phase

    three

    Number of Bearing

    one

    Power Factor

    0.8

    Protection Grade

    IP23

    Altitude

    ≤1000m

    Exciter Type

    Brush less, self-exciting

    Insulation Class, Temperature Rise

    H/H

    Frequency

    60HZ