160 KVA Cummins Power Diesel Generator 128kw 3 Phase For Livestock Farm | 6BTAA5.9-G12
In today’s livestock industry, which relies heavily on mechanization and electrification, a stable power supply serves as the lifeline for any farm. Power outages can cripple ventilation, climate control, and feeding systems, resulting in massive economic losses within a very short timeframe. Thanks to their rapid startup capabilities, robust load-bearing capacity, and reliable operation, diesel generator sets or gas generators have become indispensable power assurance equipment for all types of livestock farms—particularly in regions with unstable power grids or when utilized as emergency backup systems.
Core Application Scenarios
In the livestock industry, diesel generator sets primarily function as either “backup power sources” or “primary power sources,” ensuring that critical equipment continues to operate seamlessly in the event of a grid outage.
Livestock and Poultry Farming (Pigs, Cattle, Chickens, Ducks, etc.):
These generator sets ensure the continuous operation of ventilation systems (fans) and climate control systems (evaporative cooling pads, hot air blowers, heat lamps), thereby preventing animals from suffering heatstroke in high temperatures or frostbite in low temperatures. Simultaneously, they maintain the operation of automated feeding lines and water pumps, ensuring that animals have uninterrupted access to feed and water.
Aquaculture (Fish, Shrimp, Crabs, etc.):
This represents one of the scenarios most sensitive to power interruptions. In the event of an outage, generator sets must immediately power aeration pumps to prevent oxygen depletion in the water—a condition that can lead to mass mortality among fish and shrimp (known as “pond turnover”). Typically, large-scale losses can occur within just one hour of a power failure.
Incubation and Hatchery Operations:
These generator sets guarantee precise temperature and humidity control within incubators and climate-controlled nursery rooms. Should a power outage occur, embryonic development would be disrupted—or even halted entirely—leading directly to incubation failure.
Auxiliary Facilities:
Generator sets provide power for farm dormitory lighting, feed storage warehouses, vaccine cold storage units, water quality monitoring equipment, and other auxiliary facilities, thereby ensuring the safety and well-being of personnel as well as the security of farm supplies.
Uleengen 160 kva Cummins power diesel generator for the poultry industry, automatic start with ATS
Automatic Control Panel is the basic configuration for nobody on duty controlling generator.
HGM6120 controller, integrating digital, intelligent and network techniques, is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and three “remote” (remote control, remote measure and remote communication). The controller uses LCD display, optional display interface in many different languages with easy and reliable operation.
Each generator comes with a heavy-duty canopy, dependable engine operation, and easy to use control panel that allows for stable function not only in general conditions but also severe ones.
This delivery exemplifies our proven ability to meet the evolving needs of our customers worldwide for rapid, dependable, and quality power solutions.
For a customized diesel generator set for your application, please contact us UleenGen. If you let me know the application, we would be delighted to provide you with detailed generator information, price, and technical support to help you make the best decision for your power needs.

160KVA CUMMINS DIESEL GENERATOR UC160GFS SPECIFICATION |
|
|
Standby Power(50HZ) |
140KW/176KVA |
|
Prime Power(50HZ) |
128KW/160KVA |
|
Generator Ratings |
|
Voltage |
HZ |
Phase |
P.F |
Prime Amps |
Standby Power (KVA) |
Prime Power (KVA) |
|
380/220V |
50 |
3 |
0.8 |
243 |
176 |
160 |
|
400/230V |
50 |
3 |
0.8 |
230 |
176 |
160 |
|
415/240V |
50 |
3 |
0.8 |
223 |
176 |
160 |
Prime power (PRP): Prime power is available for an unlimited number of annual hours in available load application, in according with GB/T2820-97(EQVLso8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby power Rating (ESP): The standby power rating is application for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
|
ENGINE DATA |
|
Manufacturer /Model |
Cummins 6BTAA5.9-G12 |
|
Air intake System |
Turbocharged, Charge Air Cooled |
|
Fuel system |
BYC P7100/Electronic governor |
|
Cylinder Arrangement |
6 in LINE |
|
Displacement |
5.9L |
|
Bore and Stroke |
102*120 (MM) |
|
Compression Ratio |
17.3:1 |
|
Rated RPM |
1500rpm |
|
Rated Power at Rated RPM |
140KW |
|
Standby power at rated RPM |
150KW |
|
Governor Type |
electric |
|
Rated fuel consumption |
202g/kw.h |
|
Lub. Oil capacity |
16.4L |
|
ALTERNATOR SPECIFICATION |
|
General data |
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
|
Alternator Data |
|
Manufacture /Type |
Leroy Somer TAL-A44-K |
|
Number of Phase |
three |
|
Connecting Type |
3 Phase and 4 wire |
|
Number of Bearing |
one |
|
Power Factor |
0.8 |
|
Protection Grade |
IP23 |
|
Altitude |
≤1000m |
|
Exciter Type |
Brush less, self-exciting |
|
Insulation Class, Temperature Rise |
H/H |
|
Alternator Capacity |
160KVA |