news
Home News Company News Voltage 10.5KV 2000KVA reliable Diesel Generator Set Silent Containerized Type YC16VTD2700-D30

Table of Contents

    Voltage 10.5KV 2000KVA reliable Diesel Generator Set Silent Containerized Type YC16VTD2700-D30

    2023-11-17 13:57:15
    By Admin

    High voltage 2000KVA diesel generator set contrainerized type. powered by Yuchai YC16VTD2700-D30 engine. Engga alternator EG560GSE. high voltage 10.5KV and two units synchronization work.

    The generator sets utilized in data centers are primarily high-speed, high-power, diesel-fueled backup generators, serving as the “last line of defense” for the entire data center power supply system. In the event of a utility power outage, they must be capable of starting up and assuming the load within an extremely short timeframe—typically a matter of mere seconds—to ensure the secure operation of IT equipment.

    🏭 Core Status: Why Is It Indispensable?
    According to the Tier standards established by the authoritative international body, the Uptime Institute, and China’s Code for Design of Data Centers* (GB50174-2017), high-tier data centers (such as Tier III/IV or Grade A facilities) are mandated to be equipped with generator sets. Together with UPS (Uninterruptible Power Supply) systems, these generators form a dual-layer safeguard: the UPS handles power switching at the millisecond level, while the generator sets provide sustained power support—lasting anywhere from several hours to several days—until utility power is restored.

    🔑 Key Technical Indicators and Trends
    With the explosive growth of AI and computing power, data center power consumption has surged, placing new demands on generator sets:

    Increasing Power Capacity: While traditional server cabinets typically consume 20–30 kW, AI computing cabinets have seen their power consumption skyrocket to over 100 kW. This trend has directly driven up the power requirements for individual generator sets; currently, the 2 MW (megawatt) class has become the industry standard, with products reaching capacities of up to 3.25 MW now entering the market.

    Reliability as a Lifeline: As emergency power sources, the primary objective is not fuel efficiency, but rather absolute reliability and rapid response speed. These systems must be capable of “starting within seconds, rapidly paralleling with other units, and quickly assuming the full load.”

    Modular and Prefabricated Designs: To meet the demand for rapid data center construction, containerized generator sets have emerged as the dominant solution. These units integrate the generator, fuel supply, power distribution, cooling, and fire suppression systems—among others—into a single standard shipping container. Functioning essentially as a “mobile power plant,” this design significantly reduces the time required for on-site installation and commissioning.

     

    ENGINE DATA

     

    Manufacturer /Model

    Yuchai / YC16VTD2700-D30

    Air intake System

    Turbocharged & Intercooled

    Cylinder Arrangement

    16, V-configuration

    Displacement

    52.26L

    Bore and Stroke

    152×180mm

    Compression Ratio

    14:1

    Rated RPM

    1500rpm

    Rated power at rated RPM

    1805KW

    Max standby Power at Rated RPM

    1985KW

    Fuel supply system

    Common Rail

    Oil capacity

    280L

    Rated fuel consumption

    205.7g/kw.h

    Oil consumption

    ≤0.5g/kw.h

    Engine size

    2800×1700×1950mm

    Engine weight

    5600KG