  • 200-500kva generator set powered by the global brand engine US Cummins/UK Perkins /Germany Deutz and China brand engine Weichai / Yuchai / SDEC
  • Genset type: Silent type/Open type/ mobile trailer type
  • Voltage: 220/127V, 380/220V, 400/230V, 415/240V, 440/254V, 460/266V, 480/277V…
  • Phase: 3 Phase, Single Phase
  • Customized Control panel with Deepsea controller, Smartgen controller, ComAp controller. with remote control function, wifi monitoring, automatic start, synchronization, etc.
  • Alternator brand: Stamford, Leroy Somer, Mecc alte, Marathon, Engga, Evotec and other reliable alternators.
  • Applications: Building, School, Hospital, Factory, Airport/Station, Poultry farm, Army, Mining, Outdoor construction…
Specifications

-50hz generator (200-500kva) specification

 

Genset Model 50HZ Diesel Engine Alternator Overall Size(mm) Gross Weight(kg)

Power

(kW)

Power

(kVA)

 Model  Engine brand

Rated Power

(kW)

No. of Cylinder

Bore xStroke

(mm)

Displacement

(L)

Fuel Consumption

(L/h)

Model
UC200GF 160 200 6CTAA8.3-G2 Cummins 185 6.L 114×135 8.27 37.4 UCI274H 2500x850x1400 1400
UC225GF 180 225 6LTAA8.9-G2 Cummins 220 6.L 114×145 8.9 42.1 UCD274J 3010x1000x1700 2600
UC250GF 200 250 6LTAA8.9-G2 Cummins 220 6.L 114×145 8.9 46.7 UCD274K 3010x1000x1700 2600
UC300GF 240 300 MTAA11-G3 Cummins 265 6.L 125×147 10.8 56.1 HCI444D 3010x1000x1700 2600
UC325GF 260 325 NTA855-G2 Cummins 292 6.L 140×152 14 60.8 HCI444ES 3010x1000x1700 2800
UC350GF 280 350 NTA855-G2A Cummins 313 6.L 140×152 14 65.4 HCI444E 3010x1000x1700 2800
UC380GF 300 375 NTAA855-G7 Cummins 343 6.L 140×152 14 70.1 HCI444FS 3300x1150x1700 3000
UC400GF 320 400 NTAA855-G7 Cummins 343 6.L 140×152 14 74.8 HCI444F 3300x1150x1700 3000
UC450GF 360 450 KTA19-G3 Cummins 408 6.L 159×159 18.9 84.1 HCI544C 3300x1150x1700 4200
UC500GF 400 500 QSZ13-G3 Cummins 450 6.L 130×163 13 93.5 HCI544C 3300x1460x2100 3550
UP200GF 160 200 1106A 70TAG4 Perkins 174 6.L 105×135 7.01 37.4  UCI274H 2240x960x1590 1300
UP250GF 200 250 1206A E70TTAG3 Perkins 217 6.L 105×135 7.01 46.8  UCD274K 2430x960x1590 2170
UP300GF 240 300 1506A E88TAG5 Perkins 268 6.L 112×149 8.8 56.1  HCI444D 3030x1120x1800 2500
UP350GF 280 350 2206C E13TAG2 Perkins 305 6.L 130×157 12.5 65.5  HCI444E 3280x1130x1950 3300
UP400GF 320 400 2206C E13TAG3 Perkins 349 6.L 130×157 12.5 74.8  HCI444F 3280x1130x1950 3300
UP450GF 360 450 2506C E15TAG1 Perkins 396 6.L 137×171 15.2 84.1  S4L1D-G41 3280x1130x1950 3800
UP500GF 400 500 2506C E15TAG2 Perkins 435 6.L 137×171 15.2 93.5  S5L1D-C41 3310x1180x1950 3940
UW200GF 160 200 WP10D200E200 Weichai 182 6.L 126×130 9.726 37.4 UCI274H 2800x1000x1500 1800
UW225GF 180 225 WP10D238E200 Weichai 216 6.L 126×130 9.726 42.1 UCDI274J 2800x1000x1500 1950
UW250GF 200 250 WP10D264E200 Weichai 240 6.L 126×130 9.726 46.7 UCI274K 2800x1100x1600 2000
UW300GF 240 300 WP10D320E200 Weichai 288 6.L 126×130 9.726 56.1 HCI444D1 3100x1200x1600 2800
UW375GF 300 375 WP12D353E200 Weichai 321 6.L 126×155 11.596 70.1 HCI444FS1 3100x1200x1600 3000
UW450GF 360 450 WP13D440E310 Weichai 392 6.L 127×165 12.54 84.1 S4L1D-G41 3500×1500×1800 4000
UW500GF 400 500 WP13D490E310 Weichai 450 6.L 127×165 12.54 93.5 S5L1D-C41 3500×1500×1800 4000
UY200GF 160 200 YC6A275 D30 Yuchai 185 6.L 108×132 7.25 37 274H 2400x970x1500 2140
UY250GF 200 250 YC6M350L D20 Yuchai 235 6.L 120×145 9.84 46 274K 3100x1050x1750 2750
UY313GF 250 313 YC6MK420L D20 Yuchai 281 6.L 123×145 10.338 58 4ES 3200x1150x1750 3000
UY375GF 300 375 YC6MJ500L D21 Yuchai 321 6.L 131×145 11.726 70 TCU318B 3300x1200x1750 3100
UY450GF 360 450 YC6T600L D22 Yuchai 401 6.L 145×165 16.35 84 TCU318D 3400x1450x1970 3900
UY500GF 400 500 YC6T660L D20 Yuchai 485 6.L 145×165 16.35 93 TCU318E 3500x1450x1970 4000

 

-60hz Generator (200-500kva) specification

 

Genset Model 60HZ Diesel Engine Alternator Overall Size(mm) Gross Weight(kg)

Power

(kW)

Power

(kVA)

Model Engine brand

Rated Power

(kW)

No. of Cylinder

Bore xStroke

(mm)

Displacement

(L)

Rated Fuel Consumption

(L/h)

Model
UC210GF 168  210  6CTAA8.3-G2 Cummins 190 6 114*135 8.3 47  UCI274G 2400x920x1650 1680
UC250GF 200  250  6LTAA8.9-G2 Cummins 235 6 114*145 8.9 56  UCI274H 2750x1000x1700 2200
UC313GF 250  313  NTA855-G1 Cummins 287 6 140*152 14 65  HCI444C 3000x1000x1700 2600
UC350GF 280  350  NTA855-G1B Cummins 313 6 140*152 14 70  HCI444D 3000x1000x1700 2700
UC400GF 320  400  NTA855-G3 Cummins 358 6 140*152 14 75  HCI444ES 3000x1000x1700 2820
UC438GF 350  438  KTA19-G2 Cummins 392 6 159*159 18.9 93  HCI444FS 3250x1280x2100 3700
UC500GF 400  500  KTA19-G3 Cummins 463 6 159*159 18.9 103  HCI444F 3250x1280x2100 3800
UP200GF 160 200 1106A 70TAG3 Perkins 173 6 105*135 7.01 37.4  UCI274G 2400x810x1360 1200
UP225GF 180 225 1106D E70TAG5 Perkins 218 6 105*135 7.01 42.1  UCI274H 2400x850x1360 1200
UP288GF 230 288 1506A E88TAG3 L Perkins 257 6 112*149 8.8 53.8  UCDI274K 2650x1000x1850 1850
UP350GF 280 350 1506A E88TAG5 L Perkins 312 6 112*149 8.8 65.5  HCI444D 2650x1000x1850 2500
UP400GF 320 400 2206A E13TAG5 Perkins 349 6 130*157 12.5 74.8  HCI444ES 3280x1130x1950 3000
UP450GF 360 450 2206A E13TAG6 Perkins 381 6 130*157 12.5 84.1  HCI444FS 3280x1130x1950 3000
UP500GF 400 500 2506C E15TAG1 Perkins 435 6 137*171 15.2 93.5  S4L1D-F41 3310x1150x1950 3900
UW250GF 200 250 WP10D264E201 Weichai 240 6 126*130 9.726 46  274H 2800x1000x1500 1950
UW350GF 280 350 WP10D360E201 Weichai 327 6 126*130 9.726 65  4D 2800x1000x1500 2000
UW375GF 300 375 WP13D385E201 Weichai 350 6 126*155 11.596 70  4ES 3050x1150x1650 2800
UW450GF 360 450 WP13D460E311 Weichai 420 6 126*155 11.596 84  4F 3700x1355x2040 3900
UW500GF 400 500 WP13D510E311 Weichai 450 6 126*155 11.596 93  4G 3700x1355x2040 3900
UY250GF 200 250 YC6MK360L D20 Yuchai 240 6 123*145 10.338 47  274H 3200x1150x1750 3000
UY300GF 240 300 YC6MK420L D20 Yuchai 281 6 123*145 10.338 50  274K 3200x1150x1750 3000
UY375GF 300 375 YC6MJ515L D22 Yuchai 334 6 131*145 11.726 70  4ES 3200x1200x1750 3100
UY500GF 400 500 YC6T660L D21 Yuchai 441 6 145*165 16.35 93  4G 3500x1450x1970 4000

 

Benefits & Features

200-500kva silent diesel generator feature

✅Our 200-500kva generator silent canopy with standard  1.5-2mm steel plate and powder coating. The customized canopy is made by galvanized sheet (anti-rust) or stainless steel and it’s powder coated for the generators installed near the sea area with high humidity. and our alternator with thick epoxy coating. for the details, please consult with our team. 

✅designed with upper lifthole and forklift hole(easy to move)

✅Standard fuel tank capacity is 8 hours base fuel tank, the fuel tank capacity could be customized as cilents’ requirements as well.

✅the most popular Color is white, yellow, green, blue. the color is optional

✅Logo can be customized

✅Canopy could be customized, the color, the thickness, the materials, etc.

✅Large residential muffler for silent operation.

✅Black-finish stainless steel locks and hinges for maximum weather protection.

✅Control panel viewing window including security access doors.

✅Large access doors for easy maintenance,operation and repairs.

✅Emergency stop push button mounted on enclosure exterior

✅oil drain pump 

 

200-500kva diesel generator core Applications:

 

1. Commercial Buildings and Facilities

This is one of the most important applications for generator sets in this power range 200-500kva, primarily used for backup power to ensure core functions are maintained during utility power outages.

1.1 Data Centers and Server Rooms:

Even small and medium-sized data centers or enterprise server rooms require extremely high power continuity and quality. A 400-500 kVA generator set can ensure uninterrupted operation of critical loads such as servers, cooling systems, and monitoring systems, preventing data loss and business interruption.

1.2 Large Commercial Complexes and Shopping Malls:

To ensure customer safety and maintain stable traffic flow, backup power is required for emergency lighting, fire protection systems, security monitoring, elevators (partial or complete), cash register systems, and certain key businesses. Gensets in the 250-500 kVA range are a common choice.

1.3 High-Rise Office Buildings:

In the event of a utility power outage, these generator units provide power to elevators, fire pumps, emergency lighting, building management systems, and critical office areas, ensuring an orderly evacuation and maintaining some operational capacity.

1.4 Hotels:

Backup power is crucial to a hotel’s brand reputation and guest safety. Generator sets are needed to power front desk systems, guest room lighting, kitchen cold storage, fire protection systems, elevators, and surveillance systems to ensure an uninterrupted guest experience.

2. Industry and Manufacturing

In the industrial sector, generator sets can serve as both backup power sources and primary or peak-shaving power sources.

2,1 Production Line Support:

Sudden power outages can cause production line halts, scrapped semi-finished products, and equipment damage, resulting in significant economic losses. A high-power generator set (e.g., 400-500 kVA) can power an entire or portion of a core production line, ensuring production continuity.

2.2 Critical Industrial Equipment Support:

Backup power is provided for critical equipment such as large injection molding machines, CNC machining centers, compressors, and water pumps, preventing production interruptions and equipment damage.

2.3 Mines, Oilfields, and Offshore Operations:

In these areas, which are remote from the public power grid or face unstable grid conditions, diesel generator sets are often used as primary power sources, powering entire construction camps, exploration equipment, drilling rigs, and maintenance workshops. 500 kVA units are very common in these applications.

3. Infrastructure Construction

3.1 Hospitals:

Hospitals are the most demanding environments for backup power generator. Generators must provide seamless power switching for critical areas and equipment, such as operating rooms, ICUs (intensive care units), emergency rooms, life support systems, and medical imaging equipment (e.g., CT and MRI). High-power generators (500 kVA or above) equipped with automatic transfer systems (ATS) are typically used.

3.2 Airports and ports:

The generator sets provide backup power for critical facilities such as terminal command centers, communications systems, baggage handling systems, and navigational lighting systems, or for cranes and refrigerated container yards at ports.

3.3 Water and wastewater treatment plants:

The standby generator sets ensure that even if pumps and control systems are shut down due to utility power outages, essential water supply and wastewater treatment capabilities can be maintained to prevent public health incidents.

4. Government and Public Utilities

4.1 Government Agencies and Emergency Command Centers:

During natural disasters or emergencies, municipal power grids may be disrupted. Diesel generator sets ensure the continuous operation of government command centers, communication systems, 911/110 emergency response centers, and other facilities, forming a core component of emergency response systems.

4.2 Communication Base Stations:

Many telecom operators’ base stations and network hubs are equipped with 200-400 kVA diesel generator sets to ensure smooth mobile and fixed network operations for hours or even days after a power outage.

5. Events and Special Occasions

Concerts, sporting events, exhibitions, and other temporary events require a reliable power supply. Diesel generator sets act as mobile power sources, providing primary or backup power for stage lighting and sound systems, large screens, catering areas, and press centers, demonstrating their flexibility.

 